MIG Wire Feed Speed and Voltage: Starting-Settings Chart

Every MIG welder has stood in front of a new machine, a fresh spool and a pile of scrap wondering where to set the two knobs. Wire feed speed and voltage are the whole game on a constant-voltage MIG machine, and getting them close on the first try saves wire, gas and grinding discs. This guide gives you a practical starting-settings chart for ER70S-6 MIG wire and a simple method for tuning from there.

How Wire Feed Speed and Voltage Work Together

On a constant-voltage (CV) MIG power source you do not set amperage directly. You set wire feed speed (WFS), and the machine delivers whatever current it takes to melt that much wire. More wire per minute means more amperage, more heat and more penetration. Voltage controls arc length: higher voltage gives a longer, wider, flatter arc; lower voltage gives a shorter, tighter, more focused arc.

The two must be balanced. Too much wire for the voltage and the wire stubs into the plate. Too much voltage for the wire and the arc gets long, wandering and spattery. Your goal is to pick the WFS that gives the heat the joint needs, then trim voltage until the arc sounds and looks right.

ER70S-6 is a copper-coated, solid carbon-steel wire classified to AWS A5.18. It runs on DC+ (DCEP, reverse polarity) with either 100% CO₂ or a 75–80% argon / 20–25% CO₂ blend. Check polarity before you touch either knob; a machine left on DC– from flux-core work will never weld solid wire properly.

ER70S-6 Starting-Settings Chart

The amperage windows below are the recommended ranges published for HYW ER70S-6 wire. Because WFS drives amperage on a CV machine, use the amperage window to know where you are, and use your machine's door chart (or synergic setting) for the matching WFS and voltage numbers for your exact gas and power source.

Wire diameter Recommended amperage Where to start Typical work
.023" (0.6 mm) 30 – 90 A Low end of the door chart; short-circuit transfer Sheet metal, auto body panels
.030" (0.8 mm) 40 – 145 A Door-chart value for your plate thickness Light fabrication, 120V machines
.035" (0.9 mm) 50 – 180 A Door-chart value, then trim voltage General shop work, trailers, repair
.045" (1.2 mm) 75 – 350 A Mid-range for thick plate; upper range needs an argon-rich blend for spray Structural, heavy equipment, production

Amperage ranges are general guidelines. Optimal settings vary with base-metal thickness, joint design, shielding gas, welding position and machine. Always run a test bead on scrap of the same thickness first.

Not sure which diameter fits your plate? See our MIG wire diameter by metal thickness chart.

A 4-Step Method for Dialing In

  1. Set the basics. Confirm DC+ polarity, the correct drive rolls and contact tip for your wire size, and gas flow per your regulator and gun manufacturer.
  2. Pick WFS from the door chart. Find your wire diameter, gas and plate thickness and set the listed wire feed speed.
  3. Trim voltage by ear and eye. In short-circuit mode a well-tuned arc has a steady, crisp "frying bacon" sound. Adjust voltage in small steps until the bead wets into both toes.
  4. Adjust WFS for heat, not voltage. If you need more penetration, raise WFS and then re-trim voltage. Changing only voltage changes bead shape, not real heat input.

Reading the Bead: Quick Troubleshooting Table

What you see or hear Likely cause Adjustment
Wire stubs into the plate, gun pushes back Voltage too low for the WFS Raise voltage or lower WFS
Long, hissing arc; wire balls and burns back Voltage too high for the WFS Lower voltage or raise WFS
Tall, ropey bead sitting on top Arc too cold or too short Add a little voltage; check travel speed
Wide, flat bead with undercut Voltage too high Reduce voltage in small steps
Burn-through on thin sheet Too much heat (WFS) Lower WFS, re-trim voltage, or drop to a smaller wire
Heavy spatter with 100% CO₂ Normal for straight CO₂ Fine-tune voltage or switch to an argon/CO₂ blend

For more on gas choice, read our 100% CO₂ vs 75/25 argon guide, and for when to move beyond short-circuit, see short circuit vs spray transfer.

Where ER70S-6 Fits

  • General fabrication and structural steel
  • Automotive body, chassis and exhaust repair
  • Heavy equipment, trailers and farm machinery
  • Manufacturing, maintenance and repair (MRO)
  • Single- and multi-pass welds on carbon and low-alloy steels

Its high manganese and silicon deoxidizers help it weld cleanly over light rust and mill scale, which gives you a little more tolerance while you are still dialing in settings.

Buying Note: Spools, Drums and Pallets

HYW ER70S-6 comes in .023", .030", .035" and .045" on 10 lb, 33 lb and 44 lb spools, with multi-roll and pallet quantities available. High-volume and robotic cells can run the 550 lb bulk drum in .035" and .045" to cut spool-change downtime. Once you find settings that work, keeping the same wire on the shelf means those settings stay valid job after job.

Stock Up on ER70S-6 MIG Wire

Copper-coated, AWS A5.18 ER70S-6 in every common diameter, with spool, drum and pallet pricing for shops and distributors.

Shop ER70S-6 Spools All Mild Steel Solid Wire

FAQ

Should I set voltage or wire feed speed first?

Wire feed speed first. On a CV machine WFS sets the amperage and heat; voltage is then trimmed to match it so the arc length is right.

Why doesn't my MIG machine have an amperage knob?

Most MIG machines are constant-voltage. Amperage follows wire feed speed, so the WFS knob is effectively your heat control.

Do settings change between 100% CO₂ and a 75/25 blend?

Yes. Gas affects arc behavior and spatter, so most door charts list separate settings for each. Use the column that matches your gas and fine-tune from there.

What polarity does ER70S-6 use?

DC+ (DCEP, reverse polarity). Self-shielded flux-core often runs DC–, so check the polarity terminals when switching wire types.

What size ER70S-6 should I buy for a 120V machine?

Smaller diameters such as .023" and .030" sit comfortably within the output of most small machines. Check your machine's rated output against the amperage ranges above.

Safety: Welding produces fumes, UV radiation, heat and electrical hazards. Use proper ventilation or fume extraction, a welding helmet with the correct shade, flame-resistant clothing and gloves, and follow your machine manufacturer's instructions and applicable OSHA/ANSI Z49.1 practices.